MIL-T-62356(AT)
4.5 Quality conformance inspection.
4.5.1 Sampling. Each turret trainer produced (100 percent) shall be subjected to examination
(see 4.5.2) and acceptance tests (see 4.5.3).
4.5.2 Quality conformance examination.
4.5.2.1 Acceptable quality level. Each turret trainer shall be examined for conformance to following acceptable quality levels (AQL's) on the basis of percent defective:
Classification AQL Major 0.25
Minor 1.50
4.5.2.2 Classification of defects. For examination purposes, defects shall be classified according to MIL-STD-105, and as follows:
TABLE V. Classification of defects.
Categories Defects Method
Major:
101
102
103
104
105
106
107
108
109
110
Dimensions affecting interchangeability not within tolerance (see 3.3. and 3.3.3).
Mountings missing, improper, broken, bent
(see 3.3.3, 3.3.3.1).
Level sensors missing, improperly installed, broken (see 3.3.3.2).
Electrical junction box incomplete, improper electrical properties, improper ground
(see 3.3.3.3).
Power cable missing, incomplete, exposed
conductor, improper insulation (see 3.3.3.4). Turret improperly installed, inoperable (see 3.3.4). Missile launcher improperly installed, inoperable (see 3.3.5).
Missile launcher mounting kit improperly installed
(see 3.3.6).
Squad leader's periscope improperly installed, inoperable (see 3.3.7).
M26 periscope improperly installed, inoperable
(see 3.3.8).
Visual/SIE 1/ Visual/SIE Visual/SIE Visual/SIE
Visual
Visual/SIE Visual/SIE
Visual/SIE Visual/SIE Visual/SIE